Page 188 - Fimex Taiwan Ltd_Wiring Devices 2018
P. 188

EHC SERIES RCCB

                                                 ․ Material of Housing : Bakelite
                                                 ․ AC 110/220V
                                                 ․ Primarily Provide Protection Against Leakage And
                                                   Earth Fault
                                                 ․ Rated Frequency : 50/60Hz
                                                 ․ Rated No Action Current : 15mA
                                                   Action Time <0.1second
          1.5kA                                  ․ Electronic Tripping


            Model Type         Rated Current          Poles          Rated Voltage        Breaking Capacity

              EHCM                  30A                2P             AC 110/220V


              EHC-2                                    2P             AC 110/220V               1.5kA
                              15, 20, 30, 40, 50A
              E H C  3 -                               3 P            A C  1    1  2 / 0  2 0 V




                                                 BHC & BHCH RCCB

                                                ■․Material of Housing : Bakelite
                                                ■․AC 110/220V
                                                ■․Primarily Provide Protection Against
                                                   Leakage, Earth Fault And Short Circuit
                                                ■․Rated Frequency : 50/60Hz
                                                ■․Rated Sensitivity Current : 30mA
                                                ․Rated No Action Current : 15mA
                                                ․Action Time <0.1second
                                                ■․Electronic Tripping



                                                                                          Breaking Capacity
              Model Type         Rated Current       Poles           Rated Voltage
                                                                                             JIS Standard
                                                       1P
                 BHC
             (Standard Type)                           2P                                        5kA
                                                       3P
                                    15, 20
                                 30, 40, 50A           1P            AC 110/220V
                BHCH
         (High-Breaking Type)                          2P                                       10kA
                                                       3P















        186